ZLT76-12VDC-A Miniature relay
1.Up to 16A contact switching capability
2. Plastic sealed and flux proofed types)
3. Low height,flat construction
4. Overall dimensions
(23.0×16.0×10.5)mm
Contact load
|
Model
|
T76
|
Contact Arrangement
|
1A(SPSTNO)
|
Maximum switching current
|
16A
|
Maximum switching voltage
|
277VAC/30VDC
|
Maximum switching power
|
4432VA/480W
|
Rated load (resistive)
|
16A/277VAC;16A/30VDC
|
Performance parameter
|
Model
|
T76
|
Contact resistance
|
Max 100MΩ
|
Action time
|
≤10ms
|
Release time
|
≤5ms
|
Insulation resistance
|
Min 100MΩ (500VDC)
|
Dielectric Strength
|
Between contacts
|
AC 750VAC 50/60Hz 1min
|
Between contact coils
|
AC 2500VAC 50/60Hz 1min
|
To attack
|
Stability
|
98m/S2
|
Strength
|
980m/S2
|
Vibration
|
10~55Hz 1.5mm Double Amplitude
|
Mechanical endurance min
|
2×104
|
Electrial eddurance min
|
2×105
|
Humidity
|
5%~85%RH
|
Ambient temperature
|
-40℃~105℃
|
Weight
|
Approx.10g
|
Coil parameters (at 20°C)
|
Coil Voltage
|
Coil Resistance
|
Pick-up Voltage
70% of rated voltage
|
Drop-out Voltage
10% of rated voltage
|
Coil Power
|
Rated
|
Max
|
VDC
|
Ω±10%
|
VDC
|
VDC
|
W
|
5
|
6.5
|
70
|
3.75
|
0.25
|
0.36
|
9
|
6.5
|
225
|
6.75
|
0.45
|
12
|
6.5
|
400
|
0.9
|
0.6
|
24
|
6.5
|
1600
|
18
|
1.2
|
5
|
6.5
|
56
|
3.75
|
0.25
|
0.45
|
9
|
6.5
|
180
|
6.75
|
0.45
|
12
|
6.5
|
320
|
9
|
0.6
|
24
|
6.5
|
1280
|
18
|
1.2
|
|